Electronic Ignition Control Systems
Battery Electronic
- Part Number: MVKEIK-N/LP
- Pilot: Non-Standing Pilot
- On-Demand System: Pilot On-Demand System
- Power: 2-D Cell Battery Electronic Ignition
- Design:
- Assembly:
- Operations: On/Off Operations ONLY
- Max Inlet 14” W.C.
- Valve: Valve Temp Rating 175°
- NG: (NG) 3”-7” W.C. 88,000 BTU’s
- LP: (LP) 8”-14” W.C. 110,000 BTU’s
- Valve Breakdown
110V Electronic Ignition
- Part Number: EIS/EIS-LP
- Pilot: Non-Standing Pilot
- On-Demand System: Pilot On-Demand System
- Power: 24V Electronic Ignition
- Design: In-Wall Design
- Assembly: 6’-10’ Pilot Assembly
- Operations: On/Off Operations ONLY
- Max Inlet 14” W.C.
- Valve: Valve Temp Rating 175°
- NG: (NG) 3”-7” W.C. 200,000 BTU’s
- LP: (LP) 8”-14” W.C. 110,000 BTU’s
- Valve Breakdown
Millivolt Control Systems
Modulating Millivolt
- Part Number: MMVKR-N/LP
- Pilot: Standing Pilot System
- On-Demand System:
- Power:Variable Flame Height
- Design: Low Profile Design
- Assembly:
- Operations:
- Max Inlet 14” W.C.
- Valve: Valve Temp Rating 225°
- NG: (NG) 7” W.C. 120,000 BTU’s
- LP: (LP) 7”-14” W.C. 120,000 BTU’s
- Valve Breakdown
On/Off Millivolt
- Part Number: MVQMK-N/LP
- Pilot: Standing Pilot System
- On-Demand System:
- Power:
- Design: Low Profile Design
- Assembly:
- Operations: On/Off Operations ONLY
- Max Inlet 14” W.C.
- Valve: Valve Temp Rating 175°
- NG:(NG) 3”-5” W.C. 70,000 BTU’s
- LP:(LP) 8”-12” W.C. 110,000 BTU’s
- Valve Breakdown
On/Off High Output Millivolt
- Part Number: HCMVQMK-N/LP
- Pilot: Standing Pilot System
- On-Demand System: Standing Pilot System
- Power:High Volume Output Millivolt System
- Design:
- Assembly:
- Operations: On/Off Operations ONLY
- Max Inlet 14” W.C.
- Valve: Valve Temp Rating 175°
- NG:(NG) 3”-5” W.C. 370,000 BTU’s
- LP:(LP) 8”-12” W.C. 560,000 BTU’s
- Valve Breakdown
Safety Pilot Control Systems
Safety Pilot
- Part Number: SPQMK-N/LP
- Pilot: Standing Pilot System
- On-Demand System:
- Power:
- Design: Low Profile Design
- Assembly:
- Operations: Manual On/Off Operations ONLY
- Max Inlet 14” W.C.
- Valve: Valve Temp Rating 300°
- NG: (NG) 90,000 BTU’s
- LP: (LP) 90,000 BTU’s
- Valve Breakdown
High Output Safety Pilot
- Part Number: HCSPQ-N/LP
- Pilot: Standing Pilot System
- On-Demand System:
- Power:
- Design:
- Assembly:
- Operations: Manual On/Off Operations ONLY
- Max Inlet 14” W.C.
- Valve:Valve Temp Rating 250°
- NG: (NG) 124,000 BTU’s
- LP: (LP) 200,000 BTU’s
- Valve Breakdown
Manual Valve
- Part Number: GAS-MA
- Pilot:
- On-Demand System:
- Power:
- Design: Low Profile Design
- Assembly:
- Operations: Manual On/Off w/ Knob or Wrench Operations ONLY
- Max Inlet 14” W.C.
- Valve:Valve Temp Rating 300°
- NG: 90,000 BTU’s (NG/LP) - MA
- LP: 240,000 BTU’s (NG/LP) - MAHC
- Valve Breakdown
Outdoor Electronic Control Systems
Weather Beater
- Part Number: GAS-WBECS
- Pilot: 24” Pilot Assembly
- On-Demand System: Pilot On-Demand System
- Power: 12V Electronic Ignition / Hot Surface Ignition System
- Design:
- Assembly:
- Operations: On/Off Operations ONLY
- Max Inlet 14” W.C.
- Valve:Valve Temp Rating 175°
- NG:
- LP: 265,000 BTU (NG/LP)
- Valve Breakdown
Outdoor EIS
- Part Number: EIS-OUTDOOR/EIS-OUTDOOR-LP
- Pilot: Non-Standing Pilot / 6’-10’ Pilot Assembly
- On-Demand System: Pilot On-Demand System
- Power: 24V Electronic Ignition
- Design: In-Wall Design
- Assembly:
- Operations: On/Off Operations ONLY
- Max Inlet 14” W.C.
- Valve: Valve Temp Rating 175°
- NG: (NG) 3”-7” W.C. 200,000 BTU’s
- LP: (LP) 8”-14” W.C. 320,000 BTU’s
- Valve Breakdown
Remotes & Controllers
GCRK
- Part Number: GAS-GCRK
- Basic On/Off Operations
- RF Transmitter & Receiver
- LCD Temp Display
- Includes Batteries & Wall Plate
- Valve Breakdown
WBPB-12/24
- Part Number: WBPB-12
- Bluetooth | Wi-Fi & Manual Control
- Connect with Home Automation OR Weather Smart App
- 12/24V System
- Valve Breakdown